Rockwell Automation 21G PowerFlex 750-Series AC Drives Programming Manual User Manual
Page 135

Rockwell Automation Publication 750-PM001J-EN-P - October 2014
135
Drive Port 0 Parameters
Chapter 3
POSITION
C
O
N
TR
O
L
Po
si
ti
on
Cf
g/S
ts
727
In Pos Psn Dwell
In Positive Position Dwell
Sets dwell time for the in position detector. Position error must be within the value
specified by the in-position band P726 [In Pos Psn Band] for this amount of time before
the in-position detector sets the in-position detect bit P724 [Psn Reg Status] Bit 11
“InPsn Detect.” A momentary out-of-position indication will reset the internal timer and
clear the in-position detect bit P724 [Psn Reg Status] Bit 11 “InPsn Detect.”
Default:
Min/Max:
0.0040
0.0001 / 10.0000
RW Real
Fi
le
Grou
p
No.
Display Name
Full Name
Description
Values
Re
ad
-W
ri
te
Da
ta
T
ype