Expert parameter view (port 0) – Rockwell Automation 21G PowerFlex 750-Series AC Drives Programming Manual User Manual
Page 32

32
Rockwell Automation Publication 750-PM001J-EN-P - October 2014
Chapter 2
Parameter Organization
Expert Parameter View (Port 0)
Parameter 301 [Access Level] set to option 2 “Expert.”
File
Group
Parameters
Monitor
Metering
Output Frequency
1
Commanded SpdRef
2
Mtr Vel Fdbk
3
Commanded Trq
4
Torque Cur Fdbk
5
Flux Cur Fdbk
6
Output Current
7
Output Voltage
8
Output Power
9
Output Powr Fctr
10
DC Bus Volts
11
DC Bus Memory
12
Elapsed MWH
13
Elapsed kWH
14
Elapsed Run Time
15
Elpsd Mtr MWHrs
16
Elpsd Rgn MWHrs
17
Elpsd Mtr kWHrs
18
Elpsd Rgn kWHrs
19
Drive Data
Rated Volts
20
Rated Amps
21
Rated kW
22
Motor Control
Motor Data
Motor NP Volts
25
Motor NP Amps
26
Motor NP Hertz
27
Motor NP RPM
28
Mtr NP Pwr Units
29
Motor NP Power
30
Motor Poles
31
Mtr Ctrl Options
Motor Ctrl Mode
35
Maximum Voltage
36
Maximum Freq
37
PWM Frequency
38
Mtr Options Cfg
40
Bus Utilization
42
Flux Up Enable
43
Flux Up Time
44
Flux Down Ki
45
Flux Down Kp
46
Econ At Ref Ki
47
Econ AccDec Ki
48
Econ AccDec Kp
49
Stability Filter
50
Stab Volt Gain
51
Stab Angle Gain
52
IPM V FB HP Filt
1648
IPM SpdEst Filt
1649
IPM SpdEst Kp
1650
IPM SpdEst Ki
1651
IPM SpdEst KiAdj
1652
IPM Tran PWM
1653
IPMTran PWM Hyst
1654
IPM Tran Mode
1655
IPM TranMod Hyst
1656
IPM Tran Filt Lo
1657
IPM Tran Filt Hi
1658
IPM Tran Angle
1659
IPM Stc OfsTst K
1660
IPM Lq Cmd BW
1661
Parameters 1648…1661 used
by drive frames 1…7 only.
Volts per Hertz
Start Acc Boost
60
Run Boost
61
Break Voltage
62
Break Frequency
63
SVC Boost Filter
64
VHz Curve
65
Autotune
Autotune
70
Autotune Torque
71
IR Voltage Drop
73
Ixo Voltage Drop
74
Flux Current Ref
75
Total Inertia
76
Inertia Test Lmt
77
Encdrlss AngComp
78
Encdrlss VltComp
79
PM Cfg
80
PM PriEnc Offset
81
PM AltEnc Offset
82
PM OfstTst Cur
83
PM OfstTst CRamp
84
PM OfstTst FRamp
85
PM CEMF Voltage
86
PM IR Voltage
87
PM IXq Voltage
755
88
PM IXd Voltage
755
89
PM Vqs Reg Kp
91
PM Vqs Reg Ki
92
PM Dir Test Cur
93
PM IXqVoltage125
120
IPM_Lg_25_pct
1630
IPM_Lg_50_pct
1631
IPM_Lg_75_pct
1632
IPM_Lg_100_pct
1633
IPM_Lg_125_pct
1634
IPM_Ld_0_pct
1635
IPM_Ld_100_pct
1636
IPM PriOffstComp
1646
IPM AltOffstComp
1647
Vector Regulator
VCL Cur Reg BW
95
VCL Cur Reg Kp
96
VCL Cur Reg Ki
97
VEncdls FReg Kp
98
VEncdls FReg Ki
99
Slip Reg Enable
100
Slip Reg Ki
101
Slip Reg Kp
102
Flux Reg Enable
103
Flux Reg Ki
104
Flux Reg Kp
105
Trq Adapt Speed
106
Trq Adapt En
107
Phase Delay Comp
108
Trq Comp Mode
109
Trq Comp Mtring
110
Trq Comp Regen
111
Slip Adapt Iqs
112
SFAdapt SlewLmt
113
SFAdapt SlewRate
114
SFAdapt CnvrgLvl
115
SFAdapt CnvrgLmt
116
IPM Bus Prot
755
1629
IPMVqFFwdCemf
755
1637
IPMVqFFwdLdIdWe
755
1638
IPMVdFFwdLqIqWe
755
1639
IPM Max Cur
755
1640
IPM Max Spd
755
1641
IPM TrqTrim Kp
755
1642
IPM TrqTrim Ki
755
1643
IPM TrqTrim HLim
755
1644
IPM TrqTrim LLim
755
1645
Monit
or
Motor Con
trol