Rockwell Automation 21G PowerFlex 750-Series AC Drives Programming Manual User Manual
Page 161

Rockwell Automation Publication 750-PM001J-EN-P - October 2014
161
Drive Port 0 Parameters
Chapter 3
DI
AG
N
O
STICS
Sta
tus
940
Drive OL Count
Drive Overload Count
Indicates power unit overload (IT) in percentage. When the value reaches 100%, the
power unit overload fault occurs.
Units:
Default:
Min/Max:
%
0.00
0.00 / 200.00
RO
Real
941
IGBT Temp Pct
Insulated-Gate Bipolar Transistor Temperature Percent
Indicates IGBT junction temperature in percentage of the maximum junction
temperature.
Units:
Default:
Min/Max:
%
0.00
–/+200.00
RO
Real
942
IGBT Temp C
Insulated-Gate Bipolar Transistor Temperature Celsius
Indicates IGBT junction temperature in centigrade.
Units:
Default:
Min/Max:
DegC
0.00
–/+200.00
RO
Real
943
Drive Temp Pct
Drive Temperature Percent
Indicates operating temperature of the drive power section (heat-sink) in percentage of
the maximum heat-sink temperature.
Units:
Default:
Min/Max:
%
0.00
–/+200.00
RO
Real
944
Drive Temp C
Drive Temperature Celsius
Present operating temperature of the drive power section.
Units:
Default:
Min/Max:
DegC
0.00
–/+200.00
RO
Real
Fi
le
Grou
p
No.
Display Name
Full Name
Description
Values
Re
ad
-W
ri
te
Da
ta
T
ype