Drive Port 0 Parameters
Chapter 3
POSITION
C
O
NTR
O
L
Po
in
t t
o P
oi
n
t
775
PTP Ref Sel
Point-To-Point Reference Select
Selects a point-to-point reference source that applies to the point-to-point position
control.
Default:
Min/Max:
780
1 / 159999
RW 32-bit
Integer
776
PTP Reference
Point-To-Point Reference
Indicates output of the point-to-point position control as a reference of the position
control. When the speed/torque/position mode P313 [Actv SpTqPs Mode] is selected to
the point-to-point mode (Option 7) or the profiler mode (Option 6), this parameter
value appears on the position selected reference P722 [Psn Selected Ref].
Default:
Min/Max:
0
–2147483648 / 2147483647
RO
32-bit
Integer
777
PTP Feedback
Point-To-Point Feedback
Indicates position feedback in the point-to-point position control.
Default:
Min/Max:
0
–2147483648 / 2147483647
RO
32-bit
Integer
778
PTP Ref Scale
Point-To-Point Reference Scale
Provides count per scale value for the point-to-point position reference. The value is a
multiplier for the point-to-point reference source selected by the reference selection
P775 [PTP Ref Sel].
Default:
Min/Max:
1.00
–/+220000000.00
RW Real
779
PTP Index Preset
Point-To-Point Index Preset
Provides pre-set index value. The value sets to the point-to-point position command
P784 [PTP Command] when the point-to-point mode is index mode P771 [PTP Mode]
and the preset position bit P770 [PTP Control] Bit 3 “Preset Psn” is on.
Default:
Min/Max:
0
–2147483648 / 2147483647
RW 32-bit
Integer
780
PTP Setpoint
Point-To-Point Setpoint
Provides set point for the point-to-point position control. The value applies to the point-
to-point control when the point-to-point reference selection P775 [PTP Ref Sel] is P780.
Default:
Min/Max:
0
–2147483648 / 2147483647
RW 32-bit
Integer
781
PTP Accel Time
Point-To-Point Acceleration Time
Provides the ramp time for acceleration (time to go from zero to speed limit). The speed
limit is set by P785 [PTP Fwd Vel Lmt] and P786 [PTP Rev Vel Lmt].
Units:
Default:
Min/Max:
Secs
10.00
0.00 / 3600.00
RW Real
782
PTP Decel Time
Point-To-Point Deceleration Time
Provides the ramp time for deceleration (time to go from speed limit to zero). The speed
limit is set by P785 [PTP Fwd Vel Lmt] and P786 [PTP Rev Vel Lmt].
Units:
Default:
Min/Max:
Secs
10.00
0.00 / 3600.00
RW Real
783
PTP Speed FwdRef
Point-To-Point Speed Forward Reference
Indicates speed reference output from the point-to-point position control. Typically this
parameter is used by the drive speed loop.
Units:
Default:
Min/Max:
Hz
RPM
0.00
–/+P27 [Motor NP Hertz] x 8
–/+P28 [Motor NP RPM] x 8
RO
Real
784
PTP Command
Point-To-Point Command
Indicates position command for the point-to-point position control. The source of the
position command is selected by the speed/torque/position mode P313 [Actv SpTqPs
Mode].
Default:
Min/Max:
0
–2147483648 / 2147483647
RO
32-bit
Integer
785
PTP Fwd Vel Lmt
Point-To-Point Forward Velocity Limit
Provides the maximum forward speed reference limit from the PTP regulator.
Units:
Default:
Min/Max:
Hz
RPM
P27 [Motor NP Hertz] x 0.5
P28 [Motor NP RPM] x 0.5
0.00/P27 [Motor NP Hertz]
0.00/P28 [Motor NP RPM]
RW Real
Fi
le
Grou
p
No.
Display Name
Full Name
Description
Values
Re
ad
-W
ri
te
Da
ta
T
ype