15 parameter reference, 6 table of attributes 854 – Lenze 8400 StateLine User Manual
Page 854
15
Parameter reference
15.6
Table of attributes
854
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
LS_WriteParamList: Motor magnetizing
inductance
Linear value
22334
573E
A
4
UNSIGNED_16
10
LS_WriteParamList: Motor magnetising
current
Linear value
22333
573D
A
4
UNSIGNED_16
100
LS_WriteParamList: Auto-DCB: hold time
Linear value
22331
573B
A
4
UNSIGNED_32
1000
LS_WriteParamList: DC braking: Hold time Linear value
22330
573A
A
4
UNSIGNED_32
1000
LS_WriteParamList: Setting of motor
overload (I²xt)
Linear value
22329
5739
A
4
INTEGER_16
100
LS_WriteParamList: Oscillation damping
influence
Linear value
22326
5736
A
4
UNSIGNED_16
100
LS_WriteParamList: Filter time - oscill.
damping
Linear value
22325
5735
A
4
UNSIGNED_8
1
LS_WriteParamList: Oscillation damping
field weakening
Linear value
22324
5734
A
4
UNSIGNED_8
1
LS_WriteParamList: Moment of inertia
Linear value
22319
572F
A
4
UNSIGNED_32
100
LS_WriteParamList: Speed sensor
selection
Selection list
22315
572B
A
4
UNSIGNED_8
1
LS_WriteParamList: Sensibility - Setpoint
feedforward control
Selection list
22311
5727
A
4
UNSIGNED_8
1
LS_WriteParamList: Motor phase direction
of rotation
Selection list
22303
571F
A
4
UNSIGNED_8
1 CINH
LS_WriteParamList: Speed limitation
Linear value
22302
571E
A
8
INTEGER_16
100
LS_WriteParamList: Frequency limitation
Linear value
22301
571D
A
8
UNSIGNED_16
1
LS_WriteParamList: Motor cable length
Linear value
22300
571C
A
4
UNSIGNED_16
10
LS_WriteParamList: Motor cable cross-
section
Linear value
22299
571B
A
4
UNSIGNED_16
100
LS_WriteParamList: PSM: Maximum
motor current field weakening
Linear value
22297
5719
A
4
UNSIGNED_16
100
LS_WriteParamList: Ultimate motor
current
Linear value
22296
5718
A
4
UNSIGNED_16
10
LS_WriteParamList: Max. motor speed
Linear value
22295
5717
A
4
UNSIGNED_16
1
LS_WriteParamList: VFC: Time const. slip
comp.
Linear value
22294
5716
A
4
UNSIGNED_16
1
LS_WriteParamList: VFC: limitation V/f
+encoder
Linear value
22291
5713
A
8
UNSIGNED_16
100
LS_WriteParamList: VFC: Vp V/f +encoder
Linear value
22290
5712
A
4
UNSIGNED_16
1000
LS_WriteParamList: VFC: Ti V/f +encoder
Linear value
22289
5711
A
4
UNSIGNED_16
10
LS_WriteParamList: VFC-ECO: Vp CosPhi
controller
Linear value
22288
5710
A
4
UNSIGNED_16
1000
LS_WriteParamList: VFC-ECO: Ti CosPhi
controller
Linear value
22287
570F
A
4
UNSIGNED_16
10
LS_WriteParamList: VFC-ECO: Minimum
voltage U/f
Linear value
22286
570E
A
4
INTEGER_16
100
LS_WriteParamList: VFC-ECO: Voltage
reduction ramp
Linear value
22285
570D
A
4
UNSIGNED_8
10
LS_WriteParamList: SLVC: Field current
controller gain
Linear value
22284
570C
A
4
INTEGER_16
100
LS_WriteParamList: SLVC: Cross current
controller gain
Linear value
22283
570B
A
4
INTEGER_16
100
LS_WriteParamList: Inverter motor brake:
nAdd
Linear value
22282
570A
A
4
INTEGER_16
1
LS_WriteParamList: Inverter motor brake:
PT1 filter time
Linear value
22281
5709
A
4
INTEGER_16
10
LS_WriteParamList: Flying restart fct.:
activation
Selection list
22280
5708
A
4
UNSIGNED_8
1 CINH
LS_WriteParamList: Flying restart fct.:
process
Selection list
22279
5707
A
4
UNSIGNED_16
1
LS_WriteParamList: Flying restart: start
frequency
Linear value
22278
5706
A
4
INTEGER_16
1
Code
Name
Type
Index
Data
dec
hex
DS
DA
DT
Factor
CINH
Grayed out = display parameter (read access only)