C00370 | synctxrxtimes, C00371 | can errorcode, C00372 | can_tx_rx_error – Lenze 8400 StateLine User Manual
Page 674: C00381 | can heartbeat producer time, C00372/1, C00372/2, C00381, To 10, C00370/1, C00370/2
![background image](/manuals/566309/674/background.png)
15
Parameter reference
15.2
Parameter list | C00370
674
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00370
C00371
C00372
C00381
Parameter | Name:
C00370 | SyncTxRxTimes
Data type: INTEGER_16
Index: 24205
d
= 5E8D
h
From version 04.00.00
Display range
(min. value | unit | max. value)
-1638
μs
1638
Subcodes
Info
C00370/1
CAN Sync instant of transmission
C00370/2
Sync instant of reception
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00371 | CAN ErrorCode
Data type: UNSIGNED_16
Index: 24204
d
= 5E8C
h
From version 13.00.00
Display range
(min. value | unit | max. value)
0
65535
Subcodes
Info
C00371/1
CAN ErrorCode
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00372 | CAN_Tx_Rx_Error
Data type: UNSIGNED_8
Index: 24203
d
= 5E8B
h
Display range
(min. value | unit | max. value)
0
255
Subcodes
Info
C00372/1
CAN Tx_Error
C00372/2
CAN Rx_Error
C00372/3
CAN Tx_Overflow
C00372/4
CAN Rx_Overflow
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00381 | CAN Heartbeat producer time
Data type: UNSIGNED_16
Index: 24194
d
= 5E82
h
Time interval for the transmission of the heartbeat telegram to the consumer(s).
• The heartbeat telegram is sent automatically as soon as a time > 0 ms is set.
• Mapping of the CANopen object
(see DS301 V4.02).
Setting range
(min. value | unit | max. value)
Lenze setting
0
ms
65535 0 ms
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1