_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00490
C00495
C00496
C00497
Parameter | Name:
C00490 | Position encoder selection
Data type: UNSIGNED_8
Index: 24085
d
= 5E15
h
From version 12.00.00
Selection of the procedure of generating the actual position
Selection list
(Lenze setting printed in bold)
Info
0 No sensor: nSpeedSetValue_a
The position signal dnMotorPosAct_p is derived from the
speed setpoint nSpeedSetValue_a.
10 Encoder selection C495 or
nVoltageAngleAct_a
The position signal dnMotorPosAct_p is either calculated
from the set speed feedback (for
> 0) or from the
speed signal nMotorSpeedAct_v (for
= 0).
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00495 | Speed sensor selection
Data type: UNSIGNED_8
Index: 24080
d
= 5E10
h
Selection of the feedback system for the actual speed for motor control and display
Selection list
(Lenze setting printed in bold)
Info
0 No sensor
No sensor available for the actual speed detection
1 Sensor signal FreqIn12
Speed sensor signal is fed via the digital DI1 and DI2
inputs
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00496 | Encoder evaluation method DigIn12
Data type: UNSIGNED_8
Index: 24079
d
= 5E0F
h
From version 03.00.00
Selection list
(Lenze setting printed in bold)
Info
1 Low-resolution encoder (StateLine)
High-precision procedure for low-resolution encoders
(<=128 increments)
3 Edge-counting procedure
Simple edge counting procedure with adjustable
scanning time (
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00497 | Filter time constant
Data type: UNSIGNED_16
Index: 24078
d
= 5E0E
h
From version 03.00.00
Setting range
(min. value | unit | max. value)
0.0
ms
500.0
Subcodes
Lenze setting
Info
C00497/1
1.0 ms
FreqIn12: Encoder filter time
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10