C02866 | mctrl: special settings, C02866, C2866/3 – Lenze 8400 StateLine User Manual
Page 829: C02866/2, C2866/2, Ation, Chopper slave, C02866/3, 15 parameter reference
![background image](/manuals/566309/829/background.png)
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
829
15
Parameter reference
15.2
Parameter list | C02866
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02866
Bit 8 DC-bus supply with DC charging
connection
Bit 9 Inverter characteristics inactive
From version 12.00.00
In case of very low-inductance motors (e.g. synchronous
motor with a rated frequency of 1000 Hz) the inverter
error characteristic needs to be switched off as otherwise
the current of the device might be switched off.
0 ≡ Inverter error characteristic is active
1 ≡ Inverter error characteristic is not active
Bit 10 SCPSM: Extrapolation - actual speed
value inactive
Bit 11 TopLine: Speed encoder signal cycle
500us
Bit 12 In case of QSP - nTorqueSetValue_a
active
From version 13.00.00
Bit 13 In case of QSP - nTorquexxxLimit_a
active
From version 13.00.00
Bit 14 Sensitivity of setpoint feedf. ctrl. 16
bits
From version 14.00.00
Bit 15 SC: Dead time of speed setpoint
500us
From version 14.00.00
Subcodes
Lenze setting
Info
C02865/1
0x0000
: Special settings
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02865 | MCTRL: Special settings
Data type: UNSIGNED_16
Index: 21710
d
= 54CE
h
Parameter | Name:
C02866 | MCTRL: Special settings
Data type: UNSIGNED_8
Index: 21709
d
= 54CD
h
Activation of special functions of the internal motor control
Selection list
0 No
1 Yes
Subcodes
Lenze setting
Info
C02866/1
1: Yes
Motor ident.: Current controller par. from C075 C076
•
From version 06.00.00
Automatic motor data identification
C02866/2
0: No
Motor phase error monitoring before operation
•
From version 11.00.00
Motor phase error monitoring before operation
C02866/3
0: No
Brake chopper DC-bus slave
•
From version 12.00.00
Control of multiple internal brake choppers in the DC-
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1