_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.3.4.8
MCI
Process data assignment for fieldbus communication
Connection
Assignment
Connection
Assignment
X101/NC-NO
LA_NCtrl.bDriveFail
X4/RFR
LA_NCtrl.bFailReset
X3/A1U
LA_NCtrl.nAuxSetValue_a *
X4/DI1
LA_NCtrl.bJogSpeed1
X3/A1I
-
X4/DI2
LA_NCtrl.bJogSpeed2
X3/O1U
LA_NCtrl.nMotorSpeedAct_a *
X4/DI3
LA_NCtrl.bSetDCBrake
* 10V ≡ 100% of reference speed (
X4/DI4
LA_NCtrl.bSetSpeedCcw
X4/DO1
LA_NCtrl.bDriveReady
=
X4
DI3
DI2
DI4
GIO
24I
DI1
RFR
24E
+
+
+
+
X3
AR
A1U
GA
A1I
DO1
O1U
LP_MciIn
wCtrl
wIn2
wIn3
DriveControl
SpeedReference
TorqueReference
LP_MciOut
wState
wOut2
wOut3
DriveControlStatus
SpeedActual
TorqueActual
wOut4...16 -
COM
NC
NO
X101
CG
C
L
CH
X1
wIn4...16 -
*
Controller enable / reset error
External
supply
24 V DC
DriveReady
Actual speed value
DriveFail
Inputs only active
if NetCtrl=0
Fixed setpoint 1/3*
Fixed setpoint 2/3*
DC brake*
Change of direction of rotation*
Speed mode:
Torque mode:
Speed setpoint
Torque setpoint
(only if NetRef=0)