C00136 | communication control words, C00136/2, C00136/1 – Lenze 8400 StateLine User Manual
Page 626: 15 parameter reference
![background image](/manuals/566309/626/background.png)
15
Parameter reference
15.2
Parameter list | C00136
626
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00136
Parameter | Name:
C00136 | Communication control words
Data type: UNSIGNED_16
Index: 24439
d
= 5F77
h
Control words of the communication interfaces
Display area
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Bit 0 SwitchOn
Bit 1 DisableVoltage
Bit 2 SetQuickStop
Bit 3 EnableOperation
Bit 4 ModeSpecific_1
Bit 5 ModeSpecific_2
Bit 6 ModeSpecific_3
Bit 7 ResetFault
Bit 8 SetHalt
Bit 9 Reserved_1
Bit 10 Reserved_2
Bit 11 LenzeSpecific_1
Bit 12 LenzeSpecific_2
Bit 13 LenzeSpecific_3
Bit 14 SetFail
Bit 15 LenzeSpecific_4
Subcodes
Info
C00136/1
MCI control word
• Control word of the MCI communication interface
(communication module)
C00136/2
CAN control word
• Control word of the CAN communication interface
(CAN on board)
Read access Write access CINH PLC STOP No transfer COM MOT