15
Parameter reference
15.2
Parameter list | C02607
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02607
Parameter | Name:
C02607 | Holding brake: Status
Data type: UNSIGNED_16
Index: 21968
d
= 55D0
h
Switching status of the holding brake control
Display area
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Info
Bit 0 Brake applied
1 ≡ Holding brake is completely closed
Bit 1 Brake released
1 ≡ Holding brake is completely released
Bit 2 Feedforward control active
1 ≡ Feedforward control for holding of the load via the
motor is active before the holding brake releases.
Bit 3 Closing active
1 ≡ The brake closing time (
) expires
Bit 4 Forced release active
1 ≡ In case of automatic operation of the holding brake
control, the brake is directly released via the MCK input
bMBrakeRelease = TRUE
Bit 5 Release active
1 ≡ The brake release time (
) expires
Bit 6 Setpoint synchronisation active
1 ≡ A speed setpoint at the MCK is approached along a
defined ramp after brake release
Bit 7 Signalling contact error
Bit 8
Reserved
Bit 9
Reserved
Bit 10
Reserved
Bit 11
Reserved
Bit 12
Reserved
Bit 13
Reserved
Bit 14
Reserved
Bit 15
Reserved