C01082 | ls_writeparamlist: execute mode, C01083 | ls_writeparamlist: error status, C01084 | ls_writeparamlist: error line – Lenze 8400 StateLine User Manual
Page 776: C01083, Displays an, C01084, C01082, 15 parameter reference
![background image](/manuals/566309/776/background.png)
15
Parameter reference
15.2
Parameter list | C01082
776
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01082
C01083
C01084
Parameter | Name:
C01082 | LS_WriteParamList: Execute Mode
Data type: UNSIGNED_8
Index: 23493
d
= 5BC5
h
From version 04.00.00
: Selection of the activation method
Selection list
(Lenze setting printed in bold)
Info
0 by Execute
The writing of the parameter list is activated by a
FALSE/TRUE edge at the bExecute input.
1 by Input Select
The writing of the parameter list is carried out if a change
is made at the select inputs and if the controller is
initialised.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01083 | LS_WriteParamList: Error status
Data type: UNSIGNED_16
Index: 23492
d
= 5BC4
h
From version 04.00.00
: Error status:
• 0 = no error
• 33803 | 0x840B = invalid data type (e.g. STRING)
• 33804 | 0x840C = limit violation
• 33806 | 0x840E = invalid code
• 33813 | 0x8415 = no element of the selection list
• 33815 | 0x8417 = writing of the parameter not permitted
• 33816 | 0x8418 = writing of the parameter only permitted if controller is inhibited
• 33829 | 0x8425 = invalid subcode
• 33865 | 0x8449 = no parameter with subcodes
Display range
(min. value | unit | max. value)
0
34000
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01084 | LS_WriteParamList: Error line
Data type: UNSIGNED_8
Index: 23491
d
= 5BC3
h
From version 04.00.00
: Display of the number of list entry where the error occurred (in connection with the value
set selected via bSelectWriteValue_1 and bSelectWriteValue_2).
Display range
(min. value | unit | max. value)
0
32
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1