C00036 | dc braking: current, C00039 | fixed setpoint x (l_nset_1 n-fix), C00050 | mctrl: speed setpoint – Lenze 8400 StateLine User Manual
Page 611: C00039/1, C00039/2, C00039/3, Is used, C00050, C00036, Meterised in
![background image](/manuals/566309/611/background.png)
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
611
15
Parameter reference
15.2
Parameter list | C00036
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00036
C00039
C00050
Parameter | Name:
C00036 | DC braking: Current
Data type: INTEGER_16
Index: 24539
d
= 5FDB
h
Braking current in [%] based on rated device current (
)
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
%
200.00 50.00 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00039 | Fixed setpoint x (L_NSet_1 n-Fix)
Data type: INTEGER_16
Index: 24536
d
= 5FD8
h
FB: Fixed speed setpoints (JOG values) for the setpoint generator
Setting range
(min. value | unit | max. value)
-199.99
%
199.99
Subcodes
Lenze setting
Info
C00039/1
40.00 %
Fixed setpoint 1
C00039/2
60.00 %
Fixed setpoint 2
C00039/3
80.00 %
Fixed setpoint 3
C00039/4
0.00 %
Fixed setpoint 4
C00039/5
0.00 %
Fixed setpoint 5
C00039/6
0.00 %
Fixed setpoint 6
C00039/7
0.00 %
Fixed setpoint 7
C00039/8
0.00 %
Fixed setpoint 8
C00039/9
0.00 %
Fixed setpoint 9
C00039/10
0.00 %
Fixed setpoint 10
C00039/11
0.00 %
Fixed setpoint 11
C00039/12
0.00 %
Fixed setpoint 12
C00039/13
0.00 %
Fixed setpoint 13
C00039/14
0.00 %
Fixed setpoint 14
C00039/15
0.00 %
Fixed setpoint 15
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00050 | MCTRL: Speed setpoint
Data type: INTEGER_32
Index: 24525
d
= 5FCD
h
Display of the speed setpoint at the speed setpoint input of the motor control
Display range
(min. value | unit | max. value)
-120000
rpm
120000
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1