C00148 | ls_driveinterface: error message config, C00148, The short16 – Lenze 8400 StateLine User Manual
Page 630: 1") in, Is activated in, 15 parameter reference

15
Parameter reference
15.2
Parameter list | C00148
630
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00148
Parameter | Name:
C00148 | LS_DriveInterface: Error message config.
Data type: UNSIGNED_16
Index: 24427
d
= 5F6B
h
From version 04.00.00
Selection of the device statuses for which the bCollectedFail group error output of SB
is to be set
to TRUE.
Setting range
(min. hex value | max. hex value)
Lenze setting
0x0000
0xFFFF 0x0030 (decimal: 48)
Value is bit-coded: ( = bit set)
Info
Bit 0 SafeTorqueOff
Bit 1 ReadyToSwitchOn
Bit 2 SwitchedOn
Bit 3 TroubleQSP
From version 06.00.00
Bit 4 Trouble
Bit 5 Fault
Bit 6 Warning
Bit 7 ImpIsActive
Bit 8 CInhIsActive
Bit 9 Fail CAN_Management
Bit 10
Reserved
Bit 11
Reserved
Bit 12
Reserved
Bit 13
Reserved
Bit 14 Lock bFail at TroubleQSP
From version 11.00.00
1 ≡ The bFail output of the SB
is also
set in the "TroubleQSP" status.
• Advantage: Even in the "TroubleQSP" status, an error
occurred before can still be recognised.
Bit 15 Use 16BitFailNo.
From version 06.00.00
1 ≡ The short 16-bit error number
wStateDetermFailNoShort is provided at the
wStateDetermFailNoLow output of the
SB
.
• In this case, the wStateDetermFailNoHigh output is
"0".
• Advantage: The bus transfer of the error numbers is
possible via a data word without changing the
interconnection of the technology application.
Read access Write access CINH PLC STOP No transfer COM MOT