C02231 | ls_writeparamlist: rated motor power, C02232 | ls_writeparamlist: motor rotor resistance, C02230/1 – Lenze 8400 StateLine User Manual
Page 796: C02230/2, C02230/3, C02230/4, C02231/1, C02231/2, C02231/3, C02231/4
![background image](/manuals/566309/796/background.png)
15
Parameter reference
15.2
Parameter list | C02230
796
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02230
C02231
C02232
Parameter | Name:
C02230 | LS_WriteParamList: Override point of field weakening
Data type: INTEGER_16
Index: 22345
d
= 5749
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
-500
Hz
500
Subcodes
Lenze setting
Info
C02230/1
0 Hz
: c80_val1
C02230/2
0 Hz
: c80_val2
C02230/3
0 Hz
: c80_val3
C02230/4
0 Hz
: c80_val4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C02231 | LS_WriteParamList: Rated motor power
Data type: UNSIGNED_16
Index: 22344
d
= 5748
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
0.00
kW
500.00
Subcodes
Lenze setting
Info
C02231/1
11.00 kW
: c81_val1
C02231/2
11.00 kW
: c81_val2
C02231/3
11.00 kW
: c81_val3
C02231/4
11.00 kW
: c81_val4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C02232 | LS_WriteParamList: Motor rotor resistance
Data type: UNSIGNED_32
Index: 22343
d
= 5747
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
0
mOhm
200000
Subcodes
Lenze setting
Info
C02232/1
276 mOhm
: c82_val1
C02232/2
276 mOhm
: c82_val2
C02232/3
276 mOhm
: c82_val3
C02232/4
276 mOhm
: c82_val4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1