10 maximum torque monitoring, 11 motor speed monitoring, Motor speed monitoring – Lenze 8400 StateLine User Manual
Page 249: Maximum torque monitoring, 5motor control (mctrl)
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
249
5
Motor control (MCTRL)
5.12
Monitoring
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.12.10
Maximum torque monitoring
This function extension is only available from version 04.00.00!
If the maximum possible torque
is reached at the motor shaft, the response set in
will be carried out (Lenze setting: "0: No Reaction").
If the activated monitoring is tripped:
• The "
" error message is entered into the logbook.
• The bMctrlTorqueMax status output of the
system block will be set to TRUE.
5.12.11
Motor speed monitoring
This function extension is available from version 11.00.00!
If the drive reaches the maximally permissible motor speed (
• The error response "Fault" occurs, i.e. the inverter is inhibited and the motor changes to torque-
free operation (coasts down).
• The error message "
" is entered into the logbook.
Note!
In the Lenze setting (
= "0: No Reaction"), the maximum torque monitoring is not
activated!