C00106 | auto dcb: hold time, C00107 | dc braking: hold time, C00114 | diginx: inversion – Lenze 8400 StateLine User Manual
Page 622: C00106, C00107, Has expire, C00114, Fter the hold time, 15 parameter reference
![background image](/manuals/566309/622/background.png)
15
Parameter reference
15.2
Parameter list | C00106
622
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00106
C00107
C00114
Parameter | Name:
C00106 | Auto DCB: Hold time
Data type: UNSIGNED_32
Index: 24469
d
= 5F95
h
Hold time of the automatic DC injection brake
• The DC injection brake is applied for the time set here if the value falls below the speed setpoint set in
Setting range
(min. value | unit | max. value)
Lenze setting
0.000
s
999.000 0.500 s
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000
Parameter | Name:
C00107 | DC braking: Hold time
Data type: UNSIGNED_32
Index: 24468
d
= 5F94
h
Maximum hold time of the manual DC injection brake
• A time can be set here after which the DC injection brake is switched off automatically to prevent the motor from
thermal overload.
• When "999.000 s" is set, the hold time is infinite.
Setting range
(min. value | unit | max. value)
Lenze setting
0.000
s
999.000 999.000 s
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000
Parameter | Name:
C00114 | DigInX: Inversion
Data type: UNSIGNED_16
Index: 24461
d
= 5F8D
h
The polarity of each digital input of the device can be inverted via this bit field.
Setting range
(min. hex value | max. hex value)
Lenze setting
0x0000
0xFFFF 0x0000 (decimal: 0)
Value is bit-coded: ( = bit set)
Info
Bit 0 DI1 inverted
Inversion of digital input 1
Bit 1 DI2 inverted
Inversion of digital input 2
Bit 2 DI3 inverted
Inversion of digital input 3
Bit 3 DI4 inverted
Inversion of digital input 4
Bit 4
Reserved
Bit 5
Reserved
Bit 6
Reserved
Bit 7
Reserved
Bit 8
Reserved
Bit 9
Reserved
Bit 10
Reserved
Bit 11
Reserved
Bit 12
Reserved
Bit 13
Reserved
Bit 14
Reserved
Bit 15 CInh inverted
Inversion of digital input RFR (controller enable)
Read access Write access CINH PLC STOP No transfer COM MOT