C00076 | Ti current controller
Data type: UNSIGNED_16
Index: 24499
d
= 5FB3
h
Reset time Ti of the current controller for certain inverter functions (parameter identification, flying restart circuit)
• After the motor to be used has been selected from the motor catalogue, the suitable value can be entered
automatically.
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
ms
500.00 10.61 ms
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00079 | SC: Settings
Data type: UNSIGNED_8
Index: 24496
d
= 5FB0
h
Configuration of different options for sensorless control for synchronous motors (
)
Selection list
0 Off
1 On
Subcodes
Lenze setting
Info
C00079/1
0: Off
SC: Current controller - feedforward control
C00079/2
1: On
SC: Adapt. VP in the field weakening range
C00079/3
0: Off
SC: n-Ctrl Anti-Wind-Up
C00079/4
1: On
Field weakening for synchronous motors
•
From version 11.00.00
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00080 | Override point of field weakening
Data type: INTEGER_16
Index: 24495
d
= 5FAF
h
Offset of the override point of field weakening
• In the V/f characteristic control mode (
), the stall protection function or the max. permissible current in
the field weakening range can be adapted.
Setting range
(min. value | unit | max. value)
Lenze setting
-500
Hz
500 0 Hz
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00081 | Rated motor power
Data type: UNSIGNED_16
Index: 24494
d
= 5FAE
h
This value can be obtained from the motor nameplate. After the motor to be used has been selected from the motor
catalogue, the suitable value can be entered automatically.
Note:
It is mandatory to give the rated motor power for the sensorless vector control (
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
kW
500.00 11.00 kW
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100