Parameter reference
15.2
Parameter list | C00007
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Terminal assignment of the control modes 10 ... 16
Input/output
10: Terminals 0
12: Terminals 2
14: Terminals 11
16: Terminals 16
RFR
Controller enable / Reset of error message
DI1
Fixed setpoint 1/3
Change of direction of
rotation
Fixed setpoint 1/3
DI2
Fixed setpoint 2/3
Activate manual DC-
injection braking (DCB)
Fixed setpoint 2/3
DI3
Activate manual DC-injection
braking (DCB)
Quick stop
Motor potentiometer:
Increase speed
CW rotation quick stop
DI4
Change of direction of rotation
Motor potentiometer:
Decrease speed
CCW rotation quick stop
A1U
Main speed setpoint (10 V ≡ 100 % reference speed)
O1U
Actual speed value (10 V ≡ 100 % reference speed)
DO1
Status "Drive is ready"
Relay output
Status "Error is pending"
TA "actuating drive speed (AC Drive Profile)"
Input/output
10: Terminals 0
12: Terminals 2
14: Terminals 11
16: Terminals 16
RFR
Controller enable / Reset of error message
DI1
Fixed setpoint 1/3
Change of direction of
rotation
Fixed setpoint 1/3
DI2
Fixed setpoint 2/3
Activate manual DC-
injection braking (DCB)
Fixed setpoint 2/3
DI3
Activate manual DC-injection
braking (DCB)
Quick stop
Motor potentiometer:
Increase speed
CW rotation quick stop
DI4
Change of direction of rotation
Motor potentiometer:
Decrease speed
CCW rotation quick stop
A1U
Local speed/torque setpoint (speed mode: 10 V ≡ 100 % reference speed; torque mode: 10 V ≡ 100 % M
max
)
O1U
Actual speed value (10 V ≡ 100 % reference speed)
DO1
Status "Drive is ready"
Relay output
Status "Error is pending"
Input/output
10: Terminals 0
12: Terminals 2
14: Terminals 11
16: Terminals 16
RFR
Controller enable
Controller enable / Reset of error message
DI1
Fixed setpoint 1/3
Stop function 1
Fixed setpoint 1/3
DI2
Fixed setpoint 2/3
Stop function 2
Selection: Pre-switch off 1
Fixed setpoint 2/3
DI3
Reset error message
CW rotation quick stop
Selection: Switch-off position 1
CW rotation quick stop
DI4
Change of direction of
rotation
CCW rotation quick stop
Selection: Switch-off position 2
CCW rotation quick stop
A1U
Main speed setpoint (10 V ≡ 100 % reference speed)
O1U
-
DO1
-
Relay output
-