5
Motor control (MCTRL)
5.11
Braking operation/brake energy management
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.11.1
Setting the voltage source for braking operation
The voltage threshold for braking operation is set via the mains voltage (
) and the reduced
brake chopper threshold (
). When this "brake chopper threshold" is exceeded, the response
takes place in the DC bus. The selected function (e.g. use of a brake resistor)
serves to dissipate energy in the DC bus and reduce the DC-bus voltage.
• The "brake chopper threshold" is preset as follows so that it is higher than the specified mains
• This brake chopper threshold can be reduced by 0 ... 150 V by means of
Example:
• A 400 V device has a maximum mains voltage of 420 V AC.
• Maximum stationary DC-bus voltage: 420 V AC * 1.414 = 594 V DC
•
has been set with the selection "0" for 400 V AC mains.
• This means that
can be set to a maximum of 131 V DC (725 V DC - 594 V DC).
5.11.2
Selecting the response to an increase of the DC-bus voltage
If the brake chopper threshold resulting from
is exceeded in the DC bus, the
takes place (use of the brake resistor and/or stop of the ramp function
generator and/or inverter-motor brake).
• Optimum following of the actual speed value until the speed setpoint is reached (e.g. the motor
is stopped rapidly) is always achieved with the help of a brake resistor.
• Stopping the ramp function generator enables smoother deceleration with lower torque
oscillation..
• The inverter motor brake is available in
from version 04.00.00 onwards
. This function
enables rapid braking without a brake resistor. Torque oscillations can occur due to the
traversing dynamics.
Mains voltage
Brake chopper threshold
C00173
1-phase
3-phase
1-phase
3-phase
0
1ph 230V
3ph 400V
DC380V
DC725V
1
1ph 230V
3ph 440V
DC380V
DC735V
2
1ph 230V
3ph 480V
DC380V
DC775V
3
1ph 230V
3ph 500V
DC380V
DC790V
Stop!
The brake chopper threshold resulting from
and
must not exceed the
stabilised DC-bus voltage!