6
I/O terminals
6.1
Digital terminals
268
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Function assignment 3: DI1=FreqIn / DI2=direction
This setting in
can be used to connect a single-track encoder to terminals DI1/DI2. For this
purpose, the rotation speed is evaluated via terminal DI1 and the direction of rotation of the
encoder (LOW level ≡ CW direction of rotation) is evaluated via the DI2 terminal.
Short overview of the parameters for the frequency inputs:
Parameter
Info
Lenze setting
Value Unit
Appl.: Reference speed
1500 rpm
Frequency input DI1/DI2
Fkt. DI 1/2 10kHz
0: DI1=In1 / DI2=In2
Encoder increments at FreqIn12
128 Incr./rev.
FreqIn12: Offset
0.00 %
FreqIn12: Gain
100.00 %
PosIn12: Function
Loading with level
PosIn12: Comparison value
0
DIx: Terminal level
-
FreqIn12_nOut_v
- Incr/ms
FreqIn12_nOut_a
- %
FreqIn12_dnOut_p
- Incr
Highlighted in grey = display parameter
Q)UHT,QBD
2IIVHW
*DLQ
&
&
Q)UHT,QBY
&
&
&
&
',
0&75/B6SHHGIHHGEDFN
',
N+]
&%LW
&%LW
GQ3RV,QBS
&
& &RPSDUHYDOXH
)XQFWLRQ
E3RV,QB6WDWH
E3RV,QB/RDG
GQ3RV,QB6HWBS
&