1 truth table for activating the pre-switch off, Truth table for activating the pre-switch off, Truth table for activating the pre – Lenze 8400 StateLine User Manual
Page 368: Switch off, 7technology applications
![background image](/manuals/566309/368/background.png)
7
Technology applications
7.4
TA "Switch-off positioning"
368
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.4.2.1
Truth table for activating the pre-switch off
[7-1]
Truth table for activating the pre-switch off
Input
Function
Response in the setpoint generator
(FB L_NSet)
bJogCtrl
InputSel1
bJogCtrl
InputSel2
FALSE
FALSE
Pre-switch off inactive
No response
• The input signal bJogCtrlRfgIn is output
directly at output bRfgOut.
• The input signals bJogCtrlJog1 and
bJogCtrlJog2 are passed through 1:1 to
the downstream FB
for the
selection of fixed setpoints.
TRUE
FALSE
The bJogCtrlSlowDown1 and
bJogCtrlStop1 inputs are evaluated.
Pre-switch off can be activated
• If the slowdown function is activated via
the selected bJogCtrlSlowDown input,
fixed setpoint 2 is activated in the
setpoint generator.
• If the stop function is activated via the
selected bJogCtrlStop input, the setpoint
generator is deactivated.
FALSE
TRUE
The bJogCtrlSlowDown2 and
bJogCtrlStop2 inputs are evaluated.
TRUE
TRUE
The inputs bSJogCtrllowDown3 and
bJogCtrlStop3 are evaluated.