1 parameterisation dialog/signal flow, Parameterisation dialog/signal flow, 5motor control (mctrl) – Lenze 8400 StateLine User Manual
Page 162
5
Motor control (MCTRL)
5.7
Sensorless vector control (SLVC)
162
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
In comparison to the V/f characteristic control without feedback, the following can be achieved by
means of sensorless vector control SLVC:
• A higher maximum torque throughout the entire speed range
• A higher speed accuracy
• A higher concentricity factor
• A higher level of efficiency
• The implementation of torque-controlled operation with speed limitation
• The limitation of the maximum torque in motor and generator mode for speed-controlled
operation
5.7.1
Parameterisation dialog/signal flow
Proceed as follows to open the dialog for parameterising the motor control:
1. »Engineer« Go to the Project view and select the 8400 StateLine controller.
2. Select the Application parameters tab from the Workspace.
3. Select the motor control "4: SLVC: Vector control" from the Overview dialog level in the
Motor control list field (
):
4. Click the Motor control vector button to change to the Overview Motor control vector
dialog box.
• This dialog level only shows a simplified signal flow with the most important
parameters.
• When you click the >>More details button in the left-most position, a signal flow with
more details/parameters is displayed, as shown in the following subchapter.