C02244 | ls_writeparamlist: auto-dcb: hold time, C02245 | ls_writeparamlist: dc braking: hold time, C02244/1 – Lenze 8400 StateLine User Manual
Page 800: C02244/2, C02244/3, C02244/4, C02245/1, C02245/2, C02245/3, C02245/4
15
Parameter reference
15.2
Parameter list | C02244
800
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02244
C02245
C02246
Parameter | Name:
C02244 | LS_WriteParamList: Auto-DCB: Hold time
Data type: UNSIGNED_32
Index: 22331
d
= 573B
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
0.000
s
999.000
Subcodes
Lenze setting
Info
C02244/1
0.500 s
: c106_val1
C02244/2
0.500 s
: c106_val2
C02244/3
0.500 s
: c106_val3
C02244/4
0.500 s
: c106_val4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000
Parameter | Name:
C02245 | LS_WriteParamList: DC braking: Hold time
Data type: UNSIGNED_32
Index: 22330
d
= 573A
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
0.000
s
999.000
Subcodes
Lenze setting
Info
C02245/1
998.999 s
: c107_val1
C02245/2
998.999 s
: c107_val2
C02245/3
998.999 s
: c107_val3
C02245/4
998.999 s
: c107_val4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000
Parameter | Name:
C02246 | LS_WriteParamList: Setting of motor overload (I²xt)
Data type: INTEGER_16
Index: 22329
d
= 5739
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
0.00
%
250.00
Subcodes
Lenze setting
Info
C02246/1
100.00 %
: c120_val1
C02246/2
100.00 %
: c120_val2
C02246/3
100.00 %
: c120_val3
C02246/4
100.00 %
: c120_val4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100