Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
783
15
Parameter reference
15.2
Parameter list | C01139
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01139
C01350
Parameter | Name:
C01139 | L_Transient 1-4: Pulse duration
Data type: UNSIGNED_16
Index: 23436
d
= 5B8C
h
From version 04.00.00
Setting range
(min. value | unit | max. value)
0.000
s
60.000
Subcodes
Lenze setting
Info
C01139/1
0.000 s
: Pulse duration
C01139/2
0.000 s
: Pulse duration
C01139/3
0.000 s
: Pulse duration
C01139/4
0.000 s
: Pulse duration
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000
Parameter | Name:
C01350 | ACDrive: Drive mode
Data type: UNSIGNED_8
Index: 23225
d
= 5AB9
h
Selection list
1 Speed mode
3 Torque mode
Subcodes
Lenze setting
Info
C01350/1
1: Speed mode
ACDrive: Drive mode
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1