C00570 | resp. to controller limitations, C00571 | resp. to wrong controller setting, C00572 | brake resistor overload threshold – Lenze 8400 StateLine User Manual
Page 705: C00571/2, C00572, Old set in, C00570/4, C00571/1, C00570/1, C00570/2
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
705
15
Parameter reference
15.2
Parameter list | C00570
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00570
C00571
C00572
Parameter | Name:
C00570 | Resp. to controller limitations
Data type: UNSIGNED_8
Index: 24005
d
= 5DC5
h
Configuration of monitoring of the motor control (group 2)
Selection list
0 No Reaction
1 Fault
5 Warning
Subcodes
Lenze setting
Info
C00570/1
0: No Reaction
Response if direct-axis current controller is limited
C00570/2
0: No Reaction
Response if cross current controller is limited
C00570/3
0: No Reaction
Response if torque setpoint is limited
• Limitation of the speed controller output, the
differential setpoint control and the additive torque
with sensorless vector control (
).
C00570/4
0: No Reaction
Response if field controller is limited
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00571 | Resp. to wrong controller setting
Data type: UNSIGNED_8
Index: 24004
d
= 5DC4
h
From version 14.00.00
Selection list
0 No Reaction
1 Fault
2 Trouble
3 TroubleQuickStop
4 WarningLocked
5 Warning
6 Information
Subcodes
Lenze setting
Info
C00571/1
6: Information
Resp. to: Motor control does not match motor data
C00571/2
1: Fault
Resp. to a non-set speed controller
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00572 | Brake resistor overload threshold
Data type: UNSIGNED_8
Index: 24003
d
= 5DC3
h
From version 03.00.00
Adjustable threshold for monitoring the brake resistor utilisation
• The response for reaching the threshold can be selected in
.
Setting range
(min. value | unit | max. value)
Lenze setting
0
%
100 100 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1