731
15
Parameter reference
15.2
Parameter list | C00701
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00701
C00700/21
0: Not connected
: wSMCtrl
Interface to the optional safety system
C00700/22
0: Not connected
Reserved
C00700/23
0: Not connected
Reserved
C00700/24
0: Not connected
Reserved
C00700/25
0: Not connected
Reserved
C00700/26
0: Not connected
: wFreeIn1
Input for user signal 1
C00700/27
0: Not connected
: wFreeIn2
Input for user signal 2
C00700/28
0: Not connected
: wFreeIn3
Input for user signal 3
C00700/29
0: Not connected
: wFreeIn4
Input for user signal 4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00700 | LA_NCtrl: Analog connection list
Data type: UNSIGNED_16
Index: 23875
d
= 5D43
h
Parameter | Name:
C00701 | LA_NCtrl: Digital connection list
Data type: UNSIGNED_16
Index: 23874
d
= 5D42
h
Connection parameters for "Actuating drive speed" application: Binary inputs
• Selection of the binary output signals to be connected to the binary input signals
• The selection list contains all binary output signals which can be assigned to the binary inputs mapped by the
subcodes.
Selection list
See
selection list - digital signals
Subcodes
Lenze setting
Info
C00701/1
0: Not connected
: bCInh
Control input for setting controller inhibit
C00701/2
16008: LS_DigitalInput: bCInh
: bFailReset
Control input for error acknowledgement
C00701/3
0: Not connected
: bSetQuickstop
Control input for quick stop request
C00701/4
16002: LS_DigitalInput: bIn3
: bSetDCBrake
Control input for DC-injection braking request
C00701/5
0: Not connected
: bRFG_Stop
Control input for stopping the speed ramp function
generator
C00701/6
0: Not connected
: bRFG_0
Control input for setting the speed ramp function
generator to 0
C00701/7
0: Not connected
Reserved
C00701/8
16003: LS_DigitalInput: bIn4
: bSetSpeedCcw
Control input for change of direction of rotation
C00701/9
16000: LS_DigitalInput: bIn1
: bJogSpeed1
Selection input for fixed setpoints
C00701/10
16001: LS_DigitalInput: bIn2
: bJogSpeed2
Selection input for fixed setpoints
C00701/11
0: Not connected
: bJogSpeed4
Selection input for fixed setpoints