Ps03: par.set device invalid, Xx.0144.00002, Xx.0144.00003 – Lenze 8400 StateLine User Manual
Page 465: Xx.0144.00004, Xx.0144.00007, 9diagnostics & error management
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
465
9
Diagnostics & error management
9.9
Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
PS02: Par. set invalid [xx.0144.00002]
PS03: Par. set device invalid [xx.0144.00003]
PS04: Par. set Mci invalid [xx.0144.00004]
PS07: Par. memory module invalid [xx.0144.00007]
Response (Lenze setting printed in bold)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
The parameter set saved to the memory module is
invalid because it has not been saved completely.
• This can be due to voltage failure or caused by
removing the memory module while saving the
parameter set.
The parameter set stored in the memory module is
invalid. The reason for this can be as follows:
• Incomplete storage of the parameter set due to
voltage failure.
• The plugged-in module stems from a device with new
firmware (compare
) or from a different
device type (e.g. 8400 BaseLine).
Ensure voltage supply during the storage process and
that the module remains plugged into the slot.
Acknowledge errors via
or control word via
communication interface and then re-parameterise the
controller.
The error can only be removed by loading the Lenze
setting with the
= "1: On / start" device
command.
• In order to prevent the error, do not switch off the
voltage during the saving process.
• If the parameter set is to be transferred from one
device with a higher version to a device with a lower
version, use the "copy parameter set" function of the
keypad. Make sure that you do not use functions that
are not available in the older device.
Response (Lenze setting printed in bold)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
The parameter set saved to the memory module is
incompatible to the standard device.
• An incompatibility of the parameter set is caused e.g.
when the memory module of an 8400 HighLine is
plugged into an 8400 StateLine or the parameter set
in the memory module has a higher version than
expected by the standard device.
When the memory modules are exchanged, observe the
downward compatibility:
• OK: StateLine V2.0 to StateLine V3.0
• OK: StateLine V2.0 to HighLine V2.0
• Not OK: HighLine Vx.x to StateLine Vx.x
• Not OK: StateLine V3.0 to StateLine < V3.0
Response (Lenze setting printed in bold)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
The parameter set saved to the communication module
is incompatible to the standard device.
• An incompatibility of the parameter set is caused e.g.
when the MCI module parameters in the memory
module do not match the plugged communication
module.
When the memory modules are exchanged, observe the
downward compatibility:
• OK: StateLine V2.0 to StateLine V3.0
• OK: StateLine V2.0 to HighLine V2.0
• Not OK: HighLine Vx.x to StateLine Vx.x
• Not OK: StateLine V3.0 to StateLine < V3.0
Response (Lenze setting printed in bold)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
The parameter set saved to the memory module is
invalid.
• The error occurs while loading the parameter set.
• The memory module plugged in the device lacks a
code or a code is incorrect.
Consultation with Lenze required.