C00620 | system connection list: 16-bit, C00620, C00620/1 – Lenze 8400 StateLine User Manual
Page 714: 15 parameter reference
![background image](/manuals/566309/714/background.png)
15
Parameter reference
15.2
Parameter list | C00611
714
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00611
C00612
C00620
Parameter | Name:
C00611 | Bool connection table
Data type: UNSIGNED_16
Index: 23964
d
= 5D9C
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00612 | 32-bit connection table
Data type: UNSIGNED_16
Index: 23963
d
= 5D9B
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00620 | System connection list: 16-bit
Data type: UNSIGNED_16
Index: 23955
d
= 5D93
h
Connection parameters: 16-bit inputs
• Selection of the 16 bit output signals to be connected to the 16 bit input signals
• The selection list contains all 16 bit output signals which can be assigned to the 16 bit inputs displayed by the
subcodes.
• Non-listed subcodes are "reserved".
Selection list
See
selection list - analog signals
Subcodes
Lenze setting
Info
C00620/1
1003: LA_NCtrl: nMotorSpeedAct_a
: nOut1_a
Analog output 1: Voltage
C00620/2
0: Not connected
CAN1 output: Status word
C00620/3
0: Not connected
: wOut2
CAN1 output: Data word 2
C00620/4
0: Not connected
: wOut3
CAN1 output: Data word 3
C00620/5
0: Not connected
: wOut4
CAN1 output: Data word 4
C00620/6
0: Not connected
: wOut1
CAN2 output: Data word 1
C00620/7
0: Not connected
: wOut2
CAN2 output: Data word 2
C00620/8
0: Not connected
: wOut3
CAN2 output: Data word 3
C00620/9
0: Not connected
: wOut4
CAN2 output: Data word 4
C00620/10
0: Not connected
: wOut1
CAN3 output: Data word 1
C00620/11
0: Not connected
: wOut2
CAN3 output: Data word 2
C00620/12
0: Not connected
: wOut3
CAN3 output: Data word 3
C00620/13
0: Not connected
: wOut4
CAN3 output: Data word 4
C00620/14
0: Not connected
Display of analog signal 1
C00620/15
0: Not connected
Display of analog signal 2