Introduction: Parameterising the controller
2.3
General notes on parameters
28
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
2.3.1
Changing the parameterisation with the keypad
Keypad display and control elements
The keypad is simply plugged on the diagnostic
interface X6 ("DIAG") at the front of the standard
device.
Plugging and unplugging the keypad is possible
during operation.
LCD display
Headline
In the menu level: Menu name
In the parameter level: Parameter name
Three-part display
In the menu level: List of available menus
In the parameter level: Code/subcode and setting or actual value
Device status
Controller is switched on
Pulse inhibit active
Controller is enabled
System fault active
Controller is inhibited
"Fault" device status is active
Quick stop active
"Trouble" device status is active
Current limit exceeded
"TroubleQSP" device status is active
Speed controller 1 in the limitation
A warning is indicated