15 parameter reference, 6 table of attributes 850 – Lenze 8400 StateLine User Manual
Page 850
15
Parameter reference
15.6
Table of attributes
850
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Resp. to LS_SetError_x
Selection list
23994
5DBA
A
4
UNSIGNED_8
1
Resp. to heatsink temp.> shutdown temp.
-5°C
Selection list
23993
5DB9
E
1
UNSIGNED_8
1
Resp. to motor overtemp. PTC
Selection list
23990
5DB6
E
1
UNSIGNED_8
1
Resp. open circuit HTL encoder
Selection list
23989
5DB5
E
1
UNSIGNED_8
1
Resp. to max. speed at switching freq.
Selection list
23987
5DB3
E
1
UNSIGNED_8
1
Resp. to switch. frequency red.
Selection list
23985
5DB1
E
1
UNSIGNED_8
1
Resp. to CAN bus connection
Selection list
23983
5DAF
A
5
UNSIGNED_8
1
Resp. to CANx_IN monitoring
Selection list
23982
5DAE
A
4
UNSIGNED_8
1
Resp. to control word error
Selection list
23981
5DAD
A
2
UNSIGNED_8
1
MCK: Resp. to MCK error
Selection list
23980
5DAC
A
15
UNSIGNED_8
1
Resp. to motor phase failure
Selection list
23978
5DAA
E
1
UNSIGNED_8
1
Resp. to open circuit AINx
Selection list
23977
5DA9
A
1
UNSIGNED_8
1
Motor phase failure threshold
Linear value
23976
5DA8
E
1
INTEGER_16
100
Resp. to DC bus voltage
Selection list
23975
5DA7
A
1
UNSIGNED_8
1
Delayed resp. to fault: DC bus overvoltage Linear value
23974
5DA6
A
1
UNSIGNED_16
1000
Resp. to earth fault
Selection list
23973
5DA5
E
1
UNSIGNED_8
1
Resp. to device overload (Ixt)
Selection list
23971
5DA3
E
1
UNSIGNED_8
1
Resp. to motor overload (I²xt)
Selection list
23969
5DA1
E
1
UNSIGNED_8
1
Resp. to max. freq. feedb. DIG12/67
Selection list
23968
5DA0
E
1
UNSIGNED_8
1
Resp. to maximum torque
Selection list
23967
5D9F
E
1
UNSIGNED_8
1
Resp. to maximum current
Selection list
23966
5D9E
E
1
UNSIGNED_8
1
System connection list: 16-bit
Selection list
23955
5D93
A
111 UNSIGNED_16
1
System connection list: Bool
Selection list
23954
5D92
A
199 UNSIGNED_16
1
System connection list: Angle
Selection list
23953
5D91
A
25
UNSIGNED_16
1
L_NSet_1: Max. skip freq.
Linear value
23943
5D87
A
3
INTEGER_16
100
L_NSet_1: Min. skip freq.
Linear value
23942
5D86
A
3
INTEGER_16
100
L_NSet_1: wState
Bit coded
23941
5D85
E
1
UNSIGNED_16
1
L_NSet_1: nMaxLimit
Linear value
23940
5D84
E
1
INTEGER_16
100
L_NSet_1: nMinLimit
Linear value
23939
5D83
E
1
INTEGER_16
100
L_NSet_1: Output blocking zones
Linear value
23938
5D82
E
1
INTEGER_16
100
L_NSet_1: Output ramp rounding
Linear value
23937
5D81
E
1
INTEGER_16
100
L_NSet_1: Output add.value
Linear value
23936
5D80
E
1
INTEGER_16
100
L_NSet_1: nNOut_a
Linear value
23935
5D7F
E
1
INTEGER_16
100
Resp. to PLI monitoring
Selection list
23932
5D7C
A
1
UNSIGNED_8
1
Sensibility - Setpoint feedforward control
Selection list
23922
5D72
A
1
UNSIGNED_8
1
Source of diff. setpoint feedforward
control
Selection list
23921
5D71
A
1
UNSIGNED_8
1
L_OffsetGainP_1: Gain
Linear value
23905
5D61
E
1
INTEGER_32
10000
L_OffsetGainP_2: Gain
Linear value
23904
5D60
E
1
INTEGER_32
10000
L_OffsetGainP_3: Gain
Linear value
23903
5D5F
E
1
INTEGER_32
10000
L_Compare_1: Fct.
Selection list
23895
5D57
E
1
UNSIGNED_8
1
L_Compare_1: Hysteresis
Linear value
23894
5D56
E
1
INTEGER_16
100
L_Compare_1: Window
Linear value
23893
5D55
E
1
INTEGER_16
100
L_Compare_2: Fct.
Selection list
23890
5D52
E
1
UNSIGNED_8
1
L_Compare_2: Hysteresis
Linear value
23889
5D51
E
1
INTEGER_16
100
L_Compare_2: Window
Linear value
23888
5D50
E
1
INTEGER_16
100
L_Compare_3: Fct.
Selection list
23885
5D4D
E
1
UNSIGNED_8
1
L_Compare_3: Hysteresis
Linear value
23884
5D4C
E
1
INTEGER_16
100
L_Compare_3: Window
Linear value
23883
5D4B
E
1
INTEGER_16
100
L_OffsetGainP_1: Offset
Linear value
23879
5D47
E
1
INTEGER_16
100
Code
Name
Type
Index
Data
dec
hex
DS
DA
DT
Factor
CINH
Grayed out = display parameter (read access only)