3 using di1 as counting input, Using di1 as counting input, 6i/o terminals – Lenze 8400 StateLine User Manual
Page 270
6
I/O terminals
6.1
Digital terminals
270
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.1.1.3
Using DI1 as counting input
General information on use as a counting input
The counting input is used for counting fast edges. A 32-bit counter counts from a parameterisable
starting value up to a parameterisable comparison value and then outputs a corresponding status
signal.
• Possible counting range: 0 ... 2
31
- 1 (0 ... 2147483647)
Function assignment 4: DI1=CountIn / DI2=In
This setting in
configures the input terminal DI1 as counting input. The input terminal DI2
remains configured as "normal" digital input..
Short overview of parameters for the counting inputs:
Note!
• The starting value must be have been set so that it is smaller than the comparison
value. Otherwise, the counter will be kept at the starting value because the condition
"Count value
≥
Comparison value" has been satisfied.
• Note the maximum input frequency of the input terminal:
• DI1: f
max
= 10 kHz
Parameter
Info
Lenze setting
Value Unit
Counting input DI1
Fkt. DI 1/2 10kHz
0: DI1=In1 / DI2=In2
LS_DigitalInput: bCountIn1_Reset
0: Not connected
LS_DigitalInput: bCountIn1_LoadStartValue
0: Not connected
CountIn1: Starting value
0 incr
CountIn1: Comparison value
65535 incr
CountIn1: Counter content
- incr
DIx: Terminal level
-
Highlighted in grey = display parameter