_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00574
C00579
C00580
Parameter | Name:
C00574 | Resp. to brake resist. overtemp.
Data type: UNSIGNED_8
Index: 24001
d
= 5DC1
h
Response which is triggered if the threshold set in
for monitoring brake resistor utilisation is reached.
Selection list
(Lenze setting printed in bold)
0 No Reaction
1 Fault
5 Warning
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00579 | Resp. to max. speed/output freq. reached
Data type: UNSIGNED_8
Index: 23996
d
= 5DBC
h
Response when the max. speed limit (
) or output frequency limit (
) has been reached.
Selection list
(Lenze setting printed in bold)
0 No Reaction
1 Fault
5 Warning
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00580 | Resp. to operating system error
Data type: UNSIGNED_8
Index: 23995
d
= 5DBB
h
From version 11.00.00
Response if the required computing time of the application exceeds the available computing time.
Selection list
0 No Reaction
1 Fault
5 Warning
Subcodes
Lenze setting
Info
C00580/1
0: No Reaction
Resp. to runtime exceedance
Read access Write access CINH PLC STOP No transfer COM MOT