2 selecting the recording time/sample rate, Selecting the recording time/sample rate, 10 oscilloscope function – Lenze 8400 StateLine User Manual
Page 477
![background image](/manuals/566309/477/background.png)
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
477
10
Oscilloscope function
10.3
Operation
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
How to change a selection:
1. Go to the Vertical channel settings list field and double-click the variable to be changed in
the Name column.
2. Select a new variable in the Select variable dialog box.
3. Click Ok.
• The dialog box is closed and the selection is accepted.
How to delete a selection:
1. Go to the Vertical channel settings list field and right-click the variable to be removed to
open the context menu.
2. Select the Delete command from the context menu.
If not all available channels are assigned, you can add more variables for recording.
How to add another variable for recording:
1. Double-click the bottom line highlighted in grey in the Vertical channel settings list field.
2. Select the desired variable in the Select variable dialog box.
3. Click Ok.
• The dialog box is closed and the selection is accepted.
10.3.2
Selecting the recording time/sample rate
How to select the recording time and the sample rate:
1. Select the desired time base from the Time base list field.
• The current time base setting multiplied by ten results in the recording time.
• Since the measured data memory of the 8400 StateLine has a limited capacity, usually a
compromise is made between sample rate and recording time.
2. Enter the desired sample rate in [ms] in the Sample rate input field.