C00440
C00441
Parameter | Name:
C00440 | LS_AnalogIn1: PT1 time constant
Data type: UNSIGNED_16
Index: 24135
d
= 5E47
h
PT1 time constant (S-ramp time) for the analog input
Setting range
(min. value | unit | max. value)
0
ms
1000
Subcodes
Lenze setting
Info
C00440/1
10 ms
PT1 rounding AnalogIn1
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00441 | Decoupling AnalogOut
Data type: UNSIGNED_16
Index: 24134
d
= 5E46
h
From version 04.00.00
Configuration defining the events that lead to a decoupling of the analog output terminals.
Configuring exception handling of the output terminals
Setting range
(min. hex value | max. hex value)
Lenze setting
0x0000
0xFFFF 0x0000 (decimal: 0)
Value is bit-coded: ( = bit set)
Bit 0 SafeTorqueOff
Bit 1 ReadyToSwitchOn
Bit 2 SwitchedOn
Bit 3
Reserved
Bit 4 Trouble
Bit 5 Fault
Bit 6
Reserved
Bit 7
Reserved
Bit 8
Reserved
Bit 9 Fail CAN_Management
Bit 10
Reserved
Bit 11
Reserved
Bit 12
Reserved
Bit 13
Reserved
Bit 14
Reserved
Bit 15
Reserved
Read access Write access CINH PLC STOP No transfer COM MOT