C00464 | remote: monitoring timeout, C00465 | keypad: timeout welcome screen, C00466 | keypad: default parameter – Lenze 8400 StateLine User Manual
Page 690: C00467 | keypad: default welcome screen, C00464/1, 15 parameter reference
15
Parameter reference
15.2
Parameter list | C00464
690
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00464
C00465
C00466
C00467
C00468
Parameter | Name:
C00464 | Remote: Monitoring timeout
Data type: UNSIGNED_16
Index: 24111
d
= 5E2F
h
From version 06.00.00
Setting range
(min. value | unit | max. value)
200
ms
5000
Subcodes
Lenze setting
Info
C00464/1
2000 ms
Remote: Monitoring timeout
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00465 | Keypad: Timeout welcome screen
Data type: INTEGER_32
Index: 24110
d
= 5E2E
h
Time setting for the automatic change of the keypad display to the welcome screen
Selection list
(Lenze setting printed in bold)
0 Never show welcome screen
5 5 min
15 15 min
30 30 min
60 60 min
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00466 | Keypad: Default parameter
Data type: INTEGER_32
Index: 24109
d
= 5E2D
h
Setting of the default parameter for the keypad
Setting range
(min. value | unit | max. value)
Lenze setting
0
65535 51
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00467 | Keypad: Default welcome screen
Data type: INTEGER_32
Index: 24108
d
= 5E2C
h
Selection of the welcome screen for the keypad
Selection list
(Lenze setting printed in bold)
0 Main menu
1 Parameter list
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00468 | Service code
Data type: INTEGER_32
Index: 24107
d
= 5E2B
h
This code is for device-internal use only and must not be written to by the user!