C00472 | ls_parfree_a, C00473 | ls_parfree_v, C00474 | ls_parfree_p – Lenze 8400 StateLine User Manual
Page 692: C00472/1, 15 parameter reference
15
Parameter reference
15.2
Parameter list | C00472
692
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00472
C00473
C00474
Parameter | Name:
C00472 | LS_ParFree_a
Data type: INTEGER_16
Index: 24103
d
= 5E27
h
SB: Setting of the analog signals to be output
Setting range
(min. value | unit | max. value)
-199.99
%
199.99
Subcodes
Lenze setting
Info
C00472/1
0.00 %
Value for output nPar1_a
C00472/2
0.00 %
Value for output nPar2_a
C00472/3
100.00 %
Value for output nPar3_a
C00472/4
100.00 %
Value for output nPar4_a
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00473 | LS_ParFree_v
Data type: INTEGER_16
Index: 24102
d
= 5E26
h
SB: Setting of the speed signals to be output
Setting range
(min. value | unit | max. value)
-32767
Incr./ms
32767
Subcodes
Lenze setting
Info
C00473/1
0 incr./ms
Values for output nPar1_v ... nPar4_v
C00473/...
C00473/4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00474 | LS_ParFree_p
Data type: INTEGER_32
Index: 24101
d
= 5E25
h
Setting range
(min. value | unit | max. value)
-2147483647
Incr.
2147483647
Subcodes
Lenze setting
Info
C00474/1
0 incr.
: dnPar1_p
C00474/2
0 incr.
: dnPar2_p
C00474/3
0 incr.
: dnPar3_p
C00474/4
0 incr.
: dnPar4_p
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1