C00357 | can monitoring times, C00358 | canx_out data length, C00359 | can status – Lenze 8400 StateLine User Manual
Page 670: C00357/1, C00357/2, C00357/3, C00357/4, C00358/1, C00358/2, C00358/3
15
Parameter reference
15.2
Parameter list | C00357
670
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00357
C00358
C00359
Parameter | Name:
C00357 | CAN monitoring times
Data type: UNSIGNED_16
Index: 24218
d
= 5E9A
h
Mapping of the RPDO event time (see DS301 V4.02)
• If a value unequal to "0" is entered, the RPDO is not expected before the set time has expired.
• If the RPDO is not received within the expected time, the response set in
will be triggered.
Setting range
(min. value | unit | max. value)
0
ms
65000
Subcodes
Lenze setting
Info
C00357/1
3000 ms
CAN1_IN monitoring time
C00357/2
3000 ms
CAN2_IN monitoring time
C00357/3
3000 ms
CAN3_IN monitoring time
C00357/4
3000 ms
CAN4_IN monitoring time
•
From version 15.00.00
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00358 | CANx_OUT data length
Data type: UNSIGNED_8
Index: 24217
d
= 5E99
h
From version 03.00.00
Setting of the data length for TX PDOs
Setting range
(min. value | unit | max. value)
1
8
Subcodes
Lenze setting
Info
C00358/1
8
CAN1_OUT data length
C00358/2
8
CAN2_OUT data length
C00358/3
8
CAN3_OUT data length
C00358/4
8
CAN4_OUT data length
•
From version 15.00.00
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00359 | CAN status
Data type: UNSIGNED_8
Index: 24216
d
= 5E98
h
Selection list
(read only)
0 Operational
1 Pre-Operat.
2 Reserved
3 Reserved
4 BootUp
5 Stopped
6 Reserved
7 Reset
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1