C00177 | switching cycles, C00178 | elapsed-hour meter, C00179 | power-on time meter – Lenze 8400 StateLine User Manual
Page 643: C00177/1, C00177/2, C00177/3, C00177/4, C00177/5, C00177/6, C00177/7
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
643
15
Parameter reference
15.2
Parameter list | C00176
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00176
C00177
C00178
C00179
Parameter | Name:
C00176 | Undervoltage threshold for mains OFF
Data type: UNSIGNED_16
Index: 24399
d
= 5F4F
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00177 | Switching cycles
Data type: UNSIGNED_32
Index: 24398
d
= 5F4E
h
Counter of different switching cycles and stressful situations
Display range
(min. value | unit | max. value)
0
2147483647
Subcodes
Info
C00177/1
Number of mains switching cycles
C00177/2
Number of switching cycles of the output relay
C00177/3
Short circuit counter
C00177/4
Earth fault counter
C00177/5
"Clamp" counter
C00177/6
Counter for "safe torque off" (STO) after power-on
•
From version 12.00.00
C00177/7
Counter for controller inhibit via terminal after power-on
•
From version 12.00.00
C00177/8
Counter for pulse inhibit (IMP) after power-on
•
From version 12.00.00
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00178 | Elapsed-hour meter
Data type: UNSIGNED_32
Index: 24397
d
= 5F4D
h
Display of operating hours in seconds
Display range
(min. value | unit | max. value)
0
s
2147483647
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00179 | Power-on time meter
Data type: UNSIGNED_32
Index: 24396
d
= 5F4C
h
Display of the power-on time in seconds
Display range
(min. value | unit | max. value)
0
s
2147483647
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1