C00727 | ls_keypad digital values, C00728 | keypad analog values, C00729 | remote: setpoint selection – Lenze 8400 StateLine User Manual
Page 735: Meterised via, C00728/1, C00728/2, C00728/3, 15 parameter reference
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
735
15
Parameter reference
15.2
Parameter list | C00727
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00727
C00728
C00729
C00730
Parameter | Name:
C00727 | LS_Keypad digital values
Data type: UNSIGNED_8
Index: 23848
d
= 5D28
h
Execution of control commands for keypad operation
Setting range
(min. value | unit | max. value)
0
1
Subcodes
Lenze setting
Info
C00727/1
0
1 ≡ request quick stop
C00727/2
0
1 ≡ request DC-injection braking
C00727/3
0
1 ≡ request change of direction of rotation
C00727/4
0
1 ≡ request fixed speed setpoint 1
C00727/5
0
1 ≡ request fixed speed setpoint 2
C00727/6
0
1 ≡ motor potentiometer: request activation
C00727/7
0
1 ≡ motor potentiometer: request pos. acceleration
C00727/8
0
1 ≡ motor potentiometer: request neg. acceleration
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00728 | Keypad analog values
Data type: INTEGER_16
Index: 23847
d
= 5D27
h
Selection of different setpoints when operating via keypad
Setting range
(min. value | unit | max. value)
-199.99
%
199.99
Subcodes
Lenze setting
Info
C00728/1
100.00 %
Torque limit in motor mode
C00728/2
100.00 %
Torque limit in generator mode
C00728/3
0.00 %
Setpoint speed
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00729 | Remote: Setpoint selection
Data type: INTEGER_16
Index: 23846
d
= 5D26
h
Setting range
(min. value | unit | max. value)
-199.99
199.99
Subcodes
Lenze setting
Info
C00729/1
0.00
Remote: Setpoint keypad
C00729/2
0.00
Remote: Setpoint PC
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00730 | Oscilloscope scanning interval
Data type: UNSIGNED_32
Index: 23845
d
= 5D25
h
This code is for device-internal use only and must not be written to by the user!