9 parameterisable additional functions, 1 selection of switching frequency, Parameterisable additional functions – Lenze 8400 StateLine User Manual
Page 202: Selection of switching frequency, 5motor control (mctrl), Stop
5
Motor control (MCTRL)
5.9
Parameterisable additional functions
202
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.9
Parameterisable additional functions
5.9.1
Selection of switching frequency
The switching frequency of the inverter that can be selected in
influences the smooth
running performance and the noise generation in the connected motor as well as the power losses
in the controller.
The lower the switching frequency the higher the concentricity factor, the smaller the losses, and
the higher the noise generation.
Short overview of the relevant parameters:
Stop!
If operated at a switching frequency of 16 kHz, the output current of the controller must
not exceed the current limit values specified in the technical data! (See chapter "Rated
data" of the hardware manual.)
Note!
• Operate mid-frequency motors only at a switching frequency of 8 kHz or 16 kHz
(var./drive-opt.).
• If operated at a switching frequency of 16 kHz, the Ixt evaluation (
) is
considered including the required derating to 67 % of the rated device current at
switching frequencies of 2.4 and 8 kHz.
• Ensure that the value does not fall below the permissible switching frequency,
• if the motor is not approved for the setting switching frequency
- or -
• if a sinusoidal filter has been connected between the output of the inverter and the
motor which is not approved for the setting switching frequency.
(see section "
Preventing a decrease of the switching frequency
")
Parameter
Info
Lenze setting
Value Unit
Switching frequency
2: "8 kHz var./drive-opt."
Switching frequency reduction (temp.)
1: On
Current switching frequency
-
Max. pos. output frequency
1000 Hz
Max. neg. output frequency
1000 Hz
Bit 4:
MCTRL: Special settings 2
Option "Motor ident: Switching frequency 8 kHz"
(from version 14.00.00)
0x0000
(Off)
Highlighted in grey = display parameter