C00434 | o1u: gain, C00435 | o1u: offset, C00436 | o1u: voltage – Lenze 8400 StateLine User Manual
Page 681: C00439 | o1u: input value, C00439/1, C00436/1, 15 parameter reference
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
681
15
Parameter reference
15.2
Parameter list | C00434
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00434
C00435
C00436
C00439
Parameter | Name:
C00434 | O1U: Gain
Data type: INTEGER_16
Index: 24141
d
= 5E4D
h
Gain of the analog output
Setting range
(min. value | unit | max. value)
-199.99
%
199.99
Subcodes
Lenze setting
Info
C00434/1
100.00 %
O1U: Gain
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00435 | O1U: Offset
Data type: INTEGER_16
Index: 24140
d
= 5E4C
h
Offset of the analog output
Setting range
(min. value | unit | max. value)
-199.99
%
199.99
Subcodes
Lenze setting
Info
C00435/1
0.00 %
O1U: Offset
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00436 | O1U: Voltage
Data type: INTEGER_16
Index: 24139
d
= 5E4B
h
Display of the analog output voltage
Display range
(min. value | unit | max. value)
0.00
V
10.00
Subcodes
Info
C00436/1
O1U: Output voltage
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00439 | O1U: Input value
Data type: INTEGER_16
Index: 24136
d
= 5E48
h
Display of the input value for the analog output
Display range
(min. value | unit | max. value)
-199.99
%
199.99
Subcodes
Info
C00439/1
O1U: Input value
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100