1 signal adaptation by means of characteristic, Signal adaptation by means of characteristic, 6i/o terminals – Lenze 8400 StateLine User Manual
Page 284
6
I/O terminals
6.2
Analog terminals
284
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.2.1.1
Signal adaptation by means of characteristic
This function extension is only available from version 04.00.00!
According to the illustration below, an individual characteristic can be parameterised for the analog
input via the subcodes of
to provide different slopes and a dead band. Here, the input signal
corresponds to the X axis and the output signal corresponds to the Y axis:
[6-4]
Characteristic for analog inputs
In the »Engineer«, there is a parameterising dialog for entering the characteristic. This dialog also
displays the set characteristic graphically.
199.99 %
y
max
-y
max
-x
max
x
max
y
min
-y
min
199.99 %
-199.99 %
-199.99 %
Parameter
Info
Lenze setting
Value Unit
AIN1: (+y0) = min
0.00 %
AIN1: (+x0) = Dead band
0.00 %
AIN1: (-y0) = (-min)
0.00 %
AIN1: (-x0) = (-Dead band)
0.00 %
AIN1: (+ymax)
199.99 %
AIN1: (+xmax)
199.99 %
AIN1: (-ymax)
199.99 %
AIN1: (-xmax)
199.99 %