C00508 | pw protection config x6(diag), C00508/1, 15 parameter reference – Lenze 8400 StateLine User Manual
Page 699
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
699
15
Parameter reference
15.2
Parameter list | C00508
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00508
Parameter | Name:
C00508 | PW protection config X6(DIAG)
Data type: UNSIGNED_16
Index: 24067
d
= 5E03
h
From version 15.00.00
Configuration of the password protection for parameter access via diagnostic interface X6 ("DIAG")
Individual password protection for single communication channels
Setting range
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Info
Bit 0
Reserved
Bit 1 Parameter write protection
The diagnostics interface X6 cannot be used to write into
write/read parameters.
Bit 2 Parameter read protection
The diagnostics interface X6 cannot be used to read
write/read parameters.
Bit 3
Reserved
Bit 4
Reserved
Bit 5
Reserved
Bit 6
Reserved
Bit 7
Reserved
Bit 8
Reserved
Bit 9
Reserved
Bit 10
Reserved
Bit 11
Reserved
Bit 12
Reserved
Bit 13
Reserved
Bit 14
Reserved
Bit 15
Reserved
Subcodes
Lenze setting
Info
C00508/1
0x0006
PW protection config X6(DIAG)
Read access Write access CINH PLC STOP No transfer COM MOT