5motor control (mctrl) – Lenze 8400 StateLine User Manual
Page 108
![background image](/manuals/566309/108/background.png)
5
Motor control (MCTRL)
5.1
Motor selection/Motor data
108
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Other motor data
Click the Other motor data... button and go to the Other motor data dialog box including the motor
equivalent circuit (in the following for an asynchronous motor):
•
From version 12.00.00 onwards
,
displays the set motor type (ASM or PSM).
• Generally, a synchronous motor without speed feedback can also be operated with the
characteristic control (VFCplus)
control mode. The parameters for this control mode (e.g. V/f
base frequency) thus also have an according influence on synchronous motors.
Parameter
Info
ASM
PSM
Motor stator resistance
Motor stator leakage inductance
Motor rotor resistance
Motor magnetising current
Motor magnetising inductance
VFC: V/f base frequency
Slip compensation
SLVC: Vp speed controller
SLVC: Ti speed controller
Vp current controller
Ti current controller
Moment of inertia
VFC: Vmin boost
SLPSM: Vp speed controller
SLPSM: Ti speed controller
Appl.: Reference speed
Imax in motor mode
VFC: Time const. slip comp.
VFC-ECO: Voltage reduction ramp
VFC: Vp Imax controller