C00242 | l_pctrl_1: operating mode, C00243 | l_pctrl_1: acceleration time influence, C00244 | l_pctrl_1: deceleration time influence – Lenze 8400 StateLine User Manual
Page 653: C00245 | l_pctrl_1: pid output value, C00242, C00243, C00244, 15 parameter reference
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
653
15
Parameter reference
15.2
Parameter list | C00242
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00242
C00243
C00244
C00245
Parameter | Name:
C00242 | L_PCTRL_1: Operating mode
Data type: UNSIGNED_8
Index: 24333
d
= 5F0D
h
FB: Selection of the operating mode
• Depending on the selection, the blue switches in the displayed signal flow are set accordingly in the Engineer on
the Application parameters tab for the
Selection list
(Lenze setting printed in bold)
Info
0 Off
The input setpoint nNSet_a is output without any
changes at the output nOut_a.
1 nNSet + nNSet_PID
nNSet_a and nAct_a are used as PID input values. The
arriving nNSet_a is additively linked to the value output
by the PID element.
2 nSet_PID
nSet_a and nAct_a are used as PID input values. The
input nNSet_a is not considered.
3 nNSet_PID
nNSet_a and nAct_a are used as PID input values. The
input nSet_a is not considered.
4 nNSet + nSet_PID
nSet_a and nAct_a are used as PID input values. The
arriving nNSet_a setpoint is additively linked to the value
output by the PID element.
5 nNSet || nSet_PID
nSet_a and nAct_a are used as PID input values. The
setpoint nNSet_a is output at the output nOut_a . The
PID output value is output at the output nPIDOut_a.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00243 | L_PCTRL_1: Acceleration time influence
Data type: UNSIGNED_32
Index: 24332
d
= 5F0C
h
FB: Acceleration time for showing the PID output value
Setting range
(min. value | unit | max. value)
Lenze setting
0.000
s
999.999 5.000 s
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000
Parameter | Name:
C00244 | L_PCTRL_1: Deceleration time influence
Data type: UNSIGNED_32
Index: 24331
d
= 5F0B
h
FB: Deceleration time for masking out the PID output value
Setting range
(min. value | unit | max. value)
Lenze setting
0.000
s
999.999 5.000 s
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000
Parameter | Name:
C00245 | L_PCTRL_1: PID output value
Data type: INTEGER_16
Index: 24330
d
= 5F0A
h
FB: Display of the output value of the PID process controller
Display range
(min. value | unit | max. value)
-199.99
%
199.99
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100