Parameter | Name:
C00640 | L_NSet_1: nNOut_a
Data type: INTEGER_16
Index: 23935
d
= 5D7F
h
FB: Display of the generated main speed setpoint at the output nNOut_a
Display range
(min. value | unit | max. value)
-199.99
%
199.99
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00643 | Resp. to PLI monitoring
Data type: UNSIGNED_8
Index: 23932
d
= 5D7C
h
From version 11.00.00
Pole position identification without motion
Selection list
0 No Reaction
1 Fault
3 TroubleQuickStop
4 WarningLocked
5 Warning
6 Information
Subcodes
Lenze setting
Info
C00643/1
1: Fault
Response to PLI monitoring
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00653 | Sensibility - Setpoint feedforward control
Data type: UNSIGNED_8
Index: 23922
d
= 5D72
h
From version 12.00.00
Selection of the sensitivity of the differential setpoint feedforward control
• Depending on the selection, the number of indicated higher-order bits is evaluated.
Note:
The most significant bit determines the sign of the value, the remaining bits determine the numerical value.
Selection list
Info
0 Inactive
1 15 bits
Bit 0 ... bit 14 are evaluated
2 14 bits
Bit 0 ... bit 13 are evaluated
3 13 bits
Bit 0 ... bit 12 are evaluated
4 12 bits
Bit 0 ... bit 11 are evaluated
5 11 Bit
Bit 0 ... bit 10 are evaluated
6 10 Bit
Bit 0 ... bit 9 are evaluated
7 9 Bit
Bit 0 ... bit 8 are evaluated
Subcodes
Lenze setting
Info
C00653/1
0: Inactive
Sensibility - Setpoint feedforward control
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1