C00010 | ain1: characteristic, C00010, C00010/1 – Lenze 8400 StateLine User Manual
Page 605: C00010/2, C00010/3, C00010/4, C00010/5, C00010/6, C00010/7, C00010/8
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
605
15
Parameter reference
15.2
Parameter list | C00010
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00010
1116 SpeedACdrive|Klemme16
Application: Actuating drive speed (AC Drive Profile)
I/O level: "Terminal 16" control mode
1120 SpeedACdrive|Keypad
Application: Actuating drive speed (AC Drive Profile)
I/O level: "Keypad" control mode
1121 SpeedACdrive|PC
Application: Actuating drive speed (AC Drive Profile)
I/O level: "PC" control mode
1130 SpeedACdrive|CAN
Application: Actuating drive speed (AC Drive Profile)
I/O level: "CAN" control mode
1140 SpeedACdrive|MCI
Application: Actuating drive speed (AC Drive Profile)
I/O level: "MCI" control mode
3000 SwitchPos|Free
Application: Switch-off positioning
I/O level: Interconnection has been changed.
3010 SwitchPos|Terminal0
Application: Switch-off positioning
I/O level: "Terminals 0" control mode
3012 SwitchPos|Terminal 2
Application: Switch-off positioning
I/O level: "Terminal 2" control mode
3014 SwitchPos|Terminal 11
Application: Switch-off positioning
I/O level: "Terminal 11" control mode
3016 SwitchPos|Terminal 16
Application: Switch-off positioning
I/O level: "Terminal 16" control mode
3020 SwitchPos|Keypad
Application: Switch-off positioning
I/O level: "Keypad" control mode
3021 SwitchPos|PC
Application: Switch-off positioning
I/O level: "PC" control mode
3030 SwitchPos|CAN
Application: Switch-off positioning
I/O level: "CAN" control mode
3040 SwitchPos|MCI
Application: Switch-off positioning
I/O level: "MCI" control mode
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00008 | Original application|control source
Data type: UNSIGNED_16
Index: 24567
d
= 5FF7
h
Parameter | Name:
C00010 | AIN1: Characteristic
Data type: INTEGER_16
Index: 24565
d
= 5FF5
h
From version 04.00.00
Signal adaptation via characteristic
Setting range
(min. value | unit | max. value)
0.00
%
199.99
Subcodes
Lenze setting
Info
C00010/1
0.00 %
AIN1: (+y0) = min
C00010/2
0.00 %
AIN1: (+x0) = Dead band
C00010/3
0.00 %
AIN1: (-y0) = (-min)
C00010/4
0.00 %
AIN1: (-x0) = (-Dead band)
C00010/5
100.00 %
AIN1: (+ymax)
C00010/6
100.00 %
AIN1: (+xmax)
C00010/7
100.00 %
AIN1: (-ymax)
C00010/8
100.00 %
AIN1: (-xmax)
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100