C00442 | aout1: decoupling value, C00443 | dix: level, C00443/1 – Lenze 8400 StateLine User Manual
Page 683: C00443/2, C00442/1, 15 parameter reference
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
683
15
Parameter reference
15.2
Parameter list | C00442
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00442
C00443
Parameter | Name:
C00442 | AOut1: Decoupling value
Data type: INTEGER_16
Index: 24133
d
= 5E45
h
From version 04.00.00
Definition of the value the analog output terminals are to have in the decoupled state.
Configuring exception handling of the output terminals
Setting range
(min. value | unit | max. value)
0.00
%
100.00
Subcodes
Lenze setting
Info
C00442/1
0.00 %
AOut1_U: Decoupling value
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00443 | DIx: Level
Data type: UNSIGNED_16
Index: 24132
d
= 5E44
h
Bit coded display of the level of the digital inputs
Display area
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Info
Bit 0 DI1
Bit set = HIGH level
Bit 1 DI2
Bit 2 DI3
Bit 3 DI4
Bit 4
Reserved
Bit 5
Reserved
Bit 6
Reserved
Bit 7
Reserved
Bit 8
Reserved
Bit 9
Reserved
Bit 10
Reserved
Bit 11
Reserved
Bit 12
Reserved
Bit 13
Reserved
Bit 14
Reserved
Bit 15 CINH
Subcodes
Info
C00443/1
DIx: Terminal level
C00443/2
DIx: Output level
Read access Write access CINH PLC STOP No transfer COM MOT