4 binary delay element, 5 binary logic, Binary delay element – Lenze 8400 StateLine User Manual
Page 387: Binary logic, 7technology applications
![background image](/manuals/566309/387/background.png)
Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14
387
7
Technology applications
7.5
"GeneralPurpose" functions
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.5.4
Binary delay element
This function timely delays binary signals. On-delay and off-delay can be parameterised separately.
[7-21] GeneralPurpose function "Binary delay element"
• For a detailed functional description see FB
7.5.5
Binary logic
This function provides a binary output signal which is formed by a logic operation of the input
signals. Alternatively, you can also select a fixed binary value which is independent of the input
signals.
[7-22] GeneralPurpose function "Binary logic"
• For a detailed functional description see FB
bGPDigitalDelayOut
bGPDigitalDelayIn
C00720/1
C00720/2
C00833/66
In
Out
Parameter
Info
Lenze setting
Value Unit
L_DigitalDelay_1: On delay
0.000 s
L_DigitalDelay_1: Off delay
0.000 s
bGPLogicIn1
&
0
1
>
1
0 0 0
0 0 1
1
0
1
1
1
0
...
2
3
4
0
1
bGPLogicOut
C00821/2
C00821/1
C00821/3
C00821/8
bGPLogicIn2
bGPLogicIn3
C00820
C00833/63
C00833/64
C00833/65
Parameter
Info
Lenze setting
Value Unit
L_DigitalLogic_1: Function
0: bOut = 0
bIn1=0/bIn2=0/bIn3=0
0: FALSE
...
...
bIn1=1/bIn2=1/bIn3=1
0: FALSE